TitleInfluence of fuel mass load, oxygen supply and burning rate on emission factor and size distribution of carbonaceous particulate matter from indoor corn straw burning
AuthorsShen, Guofeng
Xue, Miao
Wei, Siye
Chen, Yuanchen
Wang, Bin
Wang, Rong
Shen, Huizhong
Li, Wei
Zhang, Yanyan
Huang, Ye
Chen, Han
Wei, Wen
Zhao, Qiuyue
Li, Bin
Wu, Haisuo
Tao, Shu
AffiliationJiangsu Acad Environm Sci, Nanjing 210036, Jiangsu, Peoples R China.
Peking Univ, Coll Urban & Environm Sci, Lab Earth Surface Proc, Beijing 100871, Peoples R China.
Keywordsindoor corn straw burning
emission factor
size distribution
influencing factor
POLYCYCLIC AROMATIC-HYDROCARBONS
RESIDENTIAL WOOD COMBUSTION
HOUSEHOLD BIOFUEL COMBUSTION
AIR-POLLUTION
BIOMASS COMBUSTION
ELEMENTAL CARBON
CARDIOVASCULAR-DISEASE
MONOXIDE EMISSIONS
AEROSOL EMISSIONS
UNITED-STATES
Issue Date2013
Publisherjournal of environmental sciences china
CitationJOURNAL OF ENVIRONMENTAL SCIENCES-CHINA.2013,25,(3),511-519.
AbstractThe uncertainty in emission estimation is strongly associated with the variation in emission factor (BF), which could be influenced by a variety of factors such as fuel properties, stove type, fire management and even methods used in measurements. The impacts of these factors are complicated and often interact with each other. Controlled burning experiments were conducted to investigate the influences of fuel mass load, air supply and burning rate on the emissions and size distributions of carbonaceous particulate matter (PM) from indoor corn straw burning in a cooking stove. The results showed that the EFs of PM (EFPM), organic carbon (EFOC) and elemental carbon (EFEC) were independent of the fuel mass load. The differences among them under different burning rates or air supply amounts were also found to be insignificant (p > 0.05) in the tested circumstances. PM from the indoor corn straw burning was dominated by fine PM with diameter less than 2.1 mu m, contributing 86.4% +/- 3.9% of the total. The size distribution of PM was influenced by the burning rate and air supply conditions. On average, EFPM, EFOC and EFEC for corn straw burned in a residential cooking stove were (3.84 +/- 1.02), (0.846 +/- 0.895) and (0.391 +/- 0.350) g/kg, respectively. EFPM, EFOC and EFEC were found to be positively correlated with each other (p < 0.05), but they were not significantly correlated with the EF of co-emitted CO, suggesting that special attention should be paid to the use of CO as a surrogate for other incomplete combustion pollutants.
URIhttp://hdl.handle.net/20.500.11897/160991
ISSN1001-0742
DOI10.1016/S1001-0742(12)60191-0
IndexedSCI(E)
EI
Appears in Collections:城市与环境学院
地表过程分析与模拟教育部重点实验室

Web of Science®



Checked on Last Week

Scopus®



Checked on Current Time

百度学术™



Checked on Current Time

Google Scholar™