Title高稳定性,高质量脉冲压缩飞秒光纤激光系统研究?
Other TitlesFemtosecond fib er laser for high-stability and high-quality pulse compression
Authors连富强
樊仲维
白振岙
刘一州
林蔚然
张晓雷
赵天卓
Affiliation中国科学院光电研究院,北京 100094
中国科学院大学,北京 100049
中国科学院光电研究院,北京,100094
北京大学,北京,100871
北京国科世纪激光技术有限公司,北京,100190
Keywords超快光学
被动锁模
可饱和吸收
啁啾
ultrafast optics
passive mode locked
saturable absorption
chirp
HIGH-POWER
AMPLIFIERS
SYSTEM
Issue Date2015
Publisher物理学报
Citation物理学报.2015,(16),164207-1-164207-7.
Abstract报道了一款用于眼科手术的高稳定性、高质量脉冲压缩飞秒光纤主振荡功率放大系统.振荡器采用混合腔方式增加了光纤双折射,改善了非线性偏振旋转锁模在低重复频率下无法自启动的缺点,提高了飞秒光纤激光器自启动锁模的稳定性.研究了脉冲预啁啾与飞秒脉冲压缩质量的关系,通过实验证明了光纤放大器的入射脉冲保持负的预啁啾状态可以得到最好的脉冲压缩结果.实验最终实现了满足自启动锁模条件的重复频率19.4 MHz、平均功率1.2 W、脉冲宽度183 fs的激光脉冲,目前这台激光器是国内首台具有自主知识产权并应用于动物角膜实验的飞秒光纤激光器.
We demonstrate a femtosecond fiber master oscillator power amplifier system of high-stability and high-quality pulse compression, which is applied to corneal refractive surgery. The nonlinear-polarization-evolution mode-locking in a hybrid-cavity Yb-fiber oscillator consisting of both polarization-maintaining (PM) and non-PM fibers is demonstrated. In this paper, the PM-fibers introduced into the mode-locked fiber oscillator partially replace non-PM fibers. This alternative approach is conducive to reducing the adverse effect of uncontrolled fiber birefringence, which originates from the on-PM fiber suffering environmental temperature fluctuation and mechanical vibration. Once the length of non-PM fiber is comparable to the fiber beat length, the uncontrolled fiber birefringence caused by environment starts to abate the laser robustness, repeatability, and reliability of mode-locking. The stability becomes notoriously worse for long-cavity Yb-fiber oscillators. The PM-fibers adopted in the mode-locked fiber oscillator could improve the mode-locked stability of nonlinear-polarization-evolution self-started with long-cavity Yb-fiber oscillators. We study the dependence of the compressed pulse quality on the parameters of input pulse pre-chirp injected into the Yb-doped fiber amplifier. Due to the nonlinear-chirp and third order dispersion, the mode-locked pulse shape in time-domain will produce distortion during power being amplified in the Yb-doped fiber amplifier. A diffraction grating to adjust the pre-chirp of the input pulse from positive value to negative value launched into the Yb-doped fiber amplifier is placed between mode-locked Yb-fiber oscillator and Yb-doped fiber amplifier. We vary the pre-chirp by changing the distance between the diffraction grating and triangular prism and then adjust the second grating pair to compress the amplified pulses into its shortest pulse duration of full-width at half maximum measured by an autocorrelator. The experimental results show that the best compression quality of mode-locked pulse occurs at the negative pre-chirp with a measured pulse width of 183 fs. Deviation from this optimum pre-chirp degrades the compressed-pulse quality and features an increased temporal pedestal. The fiber laser produces self-started mode-locking at a repetition rate of 19.4 MHz, an average power of 1.2 W, a pulse width of 183 fs. The homemade femtosecond fiber laser is used to perform surgery on ex vivo pig corneas. The surgey shows that the light burst of femtosecond laser in corneal tissues could cut pig corneas, which proves that the femtosecond fiber laser satisfies the surgical operation requirements of animal corneas.
URIhttp://hdl.handle.net/20.500.11897/414131
ISSN1000-3290
DOI10.7498/aps.64.164207
IndexedSCI(E)
EI
中文核心期刊要目总览(PKU)
中国科技核心期刊(ISTIC)
中国科学引文数据库(CSCD)
Appears in Collections:待认领

Files in This Work
There are no files associated with this item.

Web of Science®



Checked on Last Week

Scopus®



Checked on Current Time

百度学术™



Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.